GRUEN INTERNATIONAL SCHOOLS, PORT HARCOURTIC Replacement: Removing a faulty integrated circuit from a circuit board and installing a suitable replacement.
Soldering station
Hot-air rework station
Solder wire
Flux
Tweezers
Solder wick
Magnification equipment
PCB holder
Multimeter
Appropriate replacement IC
Confirm that the suspected IC is faulty.
Disconnect power.
Protect nearby components.
Apply appropriate flux.
Remove the faulty IC using suitable rework equipment.
Clean the board pads.
Inspect the pads.
Position the replacement IC correctly.
Solder/reflow it appropriately.
Inspect the connection.
Test the board.
Work in a well-ventilated area.
Avoid touching hot equipment.
Use appropriate eye protection where required.
Avoid excessive heat.
Prevent accidental short circuits.
Use suitable tools for the board.
Keep flammable materials away from heat sources.
Actual IC removal and replacement should be demonstrated by the teacher and performed only with appropriate training, equipment and supervision.
Assignment
Observe or perform a teacher-supervised IC replacement demonstration on an approved training
board.